Annealed coil tube
First, coil stock can suit routes requiring field bends when the approved wall and bend radius permit them.
Explore pancake coils →Refrigerant lines for multi-split systems
Copper VRV & VRF Tube carries refrigerant through specified multi-split system lines. Therefore, select it by outside diameter, wall thickness, temper, supply form, cleanliness and the equipment manufacturer's piping specification.
Product overview
For variable refrigerant volume and variable refrigerant flow systems, S K Metal supplies copper tubing against the specified line size and equipment requirements.
In addition, buyers should identify whether each line serves liquid, suction or discharge duty where applicable. Tube OD, wall, temper, internal cleanliness and end sealing all matter. However, allowable sizes and pressure requirements vary by refrigerant and equipment model. Therefore, follow the equipment manufacturer's installation manual and approved project design.
See the refrigerant tube enquiry checklist →
Types and configurations
First, confirm the line schedule and installation route. Then select the approved tube form, size, wall thickness and end protection.
First, coil stock can suit routes requiring field bends when the approved wall and bend radius permit them.
Explore pancake coils →In addition, straight lengths can serve runs where alignment, support spacing and specified temper are important.
Explore hard-drawn tube →However, liquid line OD and wall must come from the equipment schedule rather than an assumed standard size.
Review sizing information →Moreover, gas or suction line dimensions must follow the designated equipment and refrigerant requirements.
Prepare a line schedule →Furthermore, sealed ends and suitable packaging help preserve the specified internal cleanliness before installation.
Discuss end protection →Finally, S K Metal can review multi-unit projects against an equipment schedule, drawings, quantity and delivery stages.
Send your piping schedule →Specification guide
Therefore, a complete line schedule helps prevent errors in OD, wall, refrigerant compatibility, cleanliness and installation requirements.
Important: Do not choose refrigerant tubing by OD alone. Instead, ask the system designer to approve wall, material, temper, service pressure, routing and joining procedure against manufacturer instructions.
Applications
Because equipment and refrigerants differ, the correct tubing depends on the approved line schedule, joining method and operating conditions.
For example, specified tube connects outdoor and indoor units through an approved refrigerant circuit.
Moreover, equipment schedules define the line sizes and permitted routing for multiple indoor units.
In addition, the approved liquid line size depends on the equipment model and circuit design.
Furthermore, gas lines require the specified OD, wall, insulation and installation clearances.
However, compatible branch joints and tube sizes must follow the system maker's instructions.
Therefore, repeat purchases should follow one approved drawing, material schedule and inspection plan.
Quality and documentation
Before ordering, define the OD, wall, temper, length, end-sealing and cleanliness checks required for Copper VRV & VRF Tube. In addition, designers can review the Copper Tube Handbook for general information about copper tube and joining practices.
Discuss your material requirement →Ordering checklist
For an accurate quotation, send the equipment line schedule with the required dimensions, supply form, standard and delivery details.
First, state the equipment brand, model, refrigerant and applicable piping specification.
Next, provide OD, wall, tolerance, line role and required length for each circuit.
Then list temper, straight or coil form, internal cleanliness and end-sealing requirements.
In addition, state pressure requirements, joining method, insulation and branch references.
Finally, include lengths or coils, packaging, destination, schedule and documentation.
Frequently asked questions
In general, it forms refrigerant lines between compatible indoor, outdoor and branch components in approved variable refrigerant systems.
In addition, provide OD, wall, temper, line designation, length or coil form and quantity for every line.
No. The tube must meet the equipment maker's dimensional, material, cleanliness and pressure requirements. Therefore, submit the approved specification.
Some projects require end protection to preserve internal cleanliness. Consequently, state the sealing and packaging requirements before quotation.
The approved joining method depends on the equipment and piping specification. Therefore, installers should follow the system maker's instructions and qualified procedures.
Yes, subject to availability by order. Finally, list material, dimensional, cleanliness and traceability documents when requesting a quote.
Request a quotation
To begin, include equipment model, refrigerant, each line's OD and wall, tube form, cleanliness, quantity and delivery location. Afterward, S K Metal will review the enquiry.
Send your requirement →