Equal tee fitting
First of all, an equal tee uses the same confirmed connection size across both run ends and the branch.
Review specification details →Three-way copper fittings for branch connections
First of all, source a Copper Tee by run outside diameter, branch outside diameter, wall thickness, socket depth, joining method and quantity.
Product overview
In addition, S K Metal supplies three-way copper fittings for creating compatible branch connections in copper tube systems.
Moreover, each tee must match both run connections, the branch connection, wall thickness, socket geometry and joining method. However, a nominal tee size may not describe every outlet dimension. Therefore, buyers should provide the complete run-by-run-by-branch size and system specification before ordering.
See what to include in your tee enquiry →
Types and configurations
First of all, confirm whether the run and branch connections are equal or reducing. Then verify every socket size, depth and joining method.
First of all, an equal tee uses the same confirmed connection size across both run ends and the branch.
Review specification details →In addition, a reducing tee combines confirmed run and branch sizes within one three-way fitting.
Provide all three sizes →However, a smaller branch outlet must be identified separately from the two main run connections.
Define the branch size →Moreover, expanded sockets must be defined by mating OD, insertion depth, clearance and joining method.
Request dimensional review →Furthermore, HVAC and refrigeration enquiries should identify tube sizes, refrigerant service and cleanliness requirements.
Discuss service requirements →Finally, drawing-based run, branch, socket, centreline and wall details can be reviewed for project requirements.
Upload a dimensional drawing →Specification guide
Therefore, a complete specification helps prevent errors in run size, branch size, socket depth, orientation and joining requirements.
Important: Do not select a tee from one nominal size alone. Therefore, the system designer should approve all three connections, socket details, material, ratings and joining procedure.
Applications
Because systems differ, the correct tee depends on run and branch dimensions, flow arrangement, joining method and operating conditions.
For example, compatible tees create branch connections in an approved refrigerant piping layout.
Moreover, specified branch fittings can divide or combine compatible routes in multi-split networks.
In addition, suitable tees provide branch outlets in compatible hot and cold water pipework.
Furthermore, only specified fittings, cleanliness controls and qualified joining procedures should be used.
However, coil and equipment branches may need drawing-controlled socket and centreline dimensions.
Therefore, repeat components should be approved by drawing, sample, tolerance and inspection criteria.
Quality and documentation
Before ordering, define the run, branch, socket, centreline, wall and orientation checks required for the exact Copper Tee. In addition, designers can review the Copper Tube Handbook for general information about copper tube and joining practices.
Discuss your material requirement →Ordering checklist
For an accurate quotation, send the fitting schedule or drawing together with the complete tube and service specification.
First of all, state equal, reducing, reduced-branch, expanded-end or drawing-based configuration.
Next, provide both run ODs, branch OD, walls, socket depths, centreline dimensions and tolerances.
Then list socket, expanded, swaged or other end forms and required joining clearances.
In addition, state medium, pressure, temperature, joining method and equipment reference.
Finally, include pieces, sample approval, packaging, destination, schedule and documentation.
Frequently asked questions
In general, it creates a three-way branch connection between compatible copper tubes. Every run and branch dimension must match the system specification.
In addition, provide all three connection ODs and walls, socket bores, insertion depths, run length, branch height and tolerances.
An equal tee uses matching connection sizes. However, a reducing tee has one or more different outlets that must be identified in the stated order.
However, availability depends on run size, branch size, socket geometry and quantity. Therefore, submit the complete size schedule for review.
In general, the approved method depends on socket geometry and system specification. Consequently, state brazing, soldering, press-fit or another required method.
Yes, but availability varies by order. Therefore, list material, dimensional, inspection and traceability requirements before quotation.
Request a quotation
To begin, include both run sizes, branch size, walls, socket depths, material, service, quantity and delivery location. Afterward, S K Metal will review availability and quotation details.
Send your requirement →